<dd id="orncr"></dd>
    1. <span id="orncr"></span>
      <th id="orncr"></th><rp id="orncr"><object id="orncr"><blockquote id="orncr"></blockquote></object></rp>

        <s id="orncr"><object id="orncr"></object></s>

         
         
         Home > Product Show

        YLN-D08

        YLN-D08 Radar Water Level Gauge

        This product is not affected by environmental factors such as temperature, humidity, air pressure, rain, snow, wind and sand, thus then radar water level gauge is quite stable, with very high accuracy within its working range and no need for maintenan…

        Order Online
        • Product Principle
        • Product Features
        • Technical Parameters

        This product is not affected by environmental factors such as temperature, humidity, air pressure, rain, snow, wind and sand, thus then radar water level gauge is quite stable, with very high accuracy within its working range and no need for maintenance. It is applied to river water level, automatic monitoring of open channel water level, tail water level monitoring in front of and under the reservoir dams, surge tower (well) water level monitoring, automatic tide level monitoring system, urban water supply, and sewage level monitoring system.

        This product is not affected by environmental factors such as temperature, humidity, air pressure, rain, snow, wind and sand, thus then radar water level gauge is quite stable, with very high accuracy within its working range and no need for maintenance. It is applied to river water level, automatic monitoring of open channel water level, tail water level monitoring in front of and under the reservoir dams, surge tower (well) water level monitoring, automatic tide level monitoring system, urban water supply, and sewage level monitoring system.

        Power supply voltage

        Four-wire system

        624) V DC / RS485  Modbus  /power consumption  90mW

        Two-wire system

        DC 24V / 4~20mA / power consumption   0.75W

        Allowed ripple

        - <100Hz            Uss<lV 

         - (100~100K) Hz     Uss<l0mV

        Cable parameters

        Cable inlet/plug

         M20xl.5 cable inlet

        Terminals

         Cable section1.0mm2

        Output parameters

        Output signal

        RS485 Modbus / 4~20mA

        Protocol

        Modbus / Hart

        Resolution

         1. 6μA

        Fault signal

        Current output does not change.

        20. 5mA

        22mA

        3.9mA

        Integration time

         (036)s,adjustable

        Blind spot

        Antenna end

        Max. measuring distance 

        Small range

        30m

        Large range

        70m

        Microwave frequency

        26GHz

        Measurement interval

        About 1s(depending on parameter setting

        Adjustment time

        About 1s(depending on parameter setting

        Display resolution    

        1mm

        Working storage and transportation temperature

         (-4070) 

        Process temperature (temperature of the antenna part)

         (-40100)

        Pressure

        Normal pressure

        Shockproof

        Mechanical vibration l0m/s2, (10~150)Hz