        YLN-GL054S

        YLN-GL054S Pipeline Radar Flowmeter

        The device adopts non-contact measurement, which will not be corroded by sewage and it has greatly reduced maintenance costs. The real-time measured water level, velocity, and flow are transmitted to the monitoring center through RTU, which is conveni…

        Order Online
        • Product Principle
        • Product Features
        • Technical Parameters

        The device adopts non-contact measurement, which will not be corroded by sewage and it has greatly reduced maintenance costs. The real-time measured water level, velocity, and flow are transmitted to the monitoring center through RTU, which is convenient for real-time understanding of the operation status of underground pipeline network. It can be used for flow monitoring of smart cities, smart water services, sponge cities, ecological flows, domestic sewage, combined sewage and rainwater pipe networks.

        The device adopts non-contact measurement, which will not be corroded by sewage and it has greatly reduced maintenance costs. The real-time measured water level, velocity, and flow are transmitted to the monitoring center through RTU, which is convenient for real-time understanding of the operation status of underground pipeline network. It can be used for flow monitoring of smart cities, smart water services, sponge cities, ecological flows, domestic sewage, combined sewage and rainwater pipe networks.

        Item

        Technical Parameters

        Ranging range

        0.05~1m、0.1~2m、0.24~4m(optional

        Ranging accuracy

        ±1%FS

        Flow rate measurement range

        0.1m/s~20m/s (Related to sewage flow regime)

        Flow rate measurement range

        ±0.01m/s ; ±1%FS

        Flow rate radar electromagnetic wave frequency

        24GHz

        Data interface

        RS-485,MODBUS protocol

        Baud rate

        9600-115200bps

        Power consumption

        Work current<80mA

        Standby current<55mA(@DC12V)

        Power supply

        DC6~30V    12V recommended

        Work temperature

        -20~+60

        Protection level

        IP685m 48h